Quality is a paper trail,
not a badge.

Fasteners fail in service for three reasons: the wrong property class, a coating under weight, or a thread that was never gauged. Our inspection is built around those three, and the records travel with the lot.

Micrometer inspection of a hex bolt on a QA bench
Inspection stages

Three gates before packing

Gate 01

Incoming material

Wire rod and bar checked against the heat number: grade, diameter, surface condition and hardness where the class depends on it.

Gate 02

In process

Heading and rolling checked for head height, thread length and pitch; heat treatment checked for tensile, proof and hardness on sample lots.

Gate 03

Before packing

Thread gauging, bearing area, coating thickness or weight, and marking. Parts that miss the standard go back, not into the carton.

Records

What you receive

Material certificate, dimensional report, coating result and packing list — issued against the lot number printed on the label.

Tests we run

Tensile, proof, hardness, coating

Tensile strengthPer ISO 898-1 for the property class ordered; 8.8, 10.9 and 12.9 confirmed on sample lots.
Proof loadLoaded to the class minimum without permanent set, checked on the same sample as tensile.
HardnessRockwell or Vickers depending on size, with the core and surface read separately after heat treatment.
Coating weightZinc plating and hot-dip galvanising checked by weight or thickness; Dacromet by coating mass.
ThreadGo / no-go gauges for the class of fit, plus pitch and flank check on the first-off part.
DimensionsHead height, across corners, thread length, bearing diameter — against the tables of the standard ordered.
Third-party inspection (SGS, BV, TÜV) can be arranged on request, at your cost, before the container is sealed.
Thread inspection close-up
Documents

Available with every shipment

A

Material certificate

Grade, heat number and chemical composition for the lot.

B

Dimensional report

Measured values against the standard's tables, per size in the lot.

C

Coating result

Thickness or coating weight per finish, with the test method noted.

D

Packing list

Carton count, net and gross weight, lot numbers, marks and dimensions.

Want the inspection plan for a specific part?

Send the standard number and the property class. We reply with the test points, sampling plan and documents that will travel with the lot.